mkb06-adapt_com(1).pdf
(
15 KB
)
Pobierz
mk:@MSITStore:K:\ansys61\docu\english\ansyshelp.chm::/Hlp_C_ADA
ADAPT
Strona 1 z 2
Main TOC
•
Using Help
•
Copyright
Commands Reference
>
A Commands
>ADAPT
Prev
Next
ADAPT
,
NSOLN
,
STARGT
,
TTARGT
,
FACMN
,
FACMX
,
KYKPS
,
KYMAC
— Adaptively meshes and
solves a model.
SOLUTION
:
Analysis Options
MP ME ST PR ED
NSOLN
Number of solutions allowed (1 or more) (defaults to 5).
STARGT
Target percentage for structural percent error in energy norm (SEPC) (defaults to 5). If -1, no
target value is used.
TTARGT
Target percentage for thermal percent error in energy norm (TEPC) (defaults to 1). If -1, no
target value is used.
FACMN
Minimum factor for the keypoint element size changes (defaults to 0.25).
FACMX
Maximum factor for the keypoint element size changes (defaults to 2.0).
KYKPS
Specifies whether element size is to be modified at selected keypoints:
0 --
Modify element size regardless of selected keypoint set (default).
1 --
Modify element size only at selected keypoints.
KYMAC
mk:@MSITStore:K:\ansys61\docu\english\ansyshelp.chm::/Hlp_C_ADAPT.html
2002-11-21
ADAPT
Strona 2 z 2
Specifies which user-written auxiliary macro files are to be used:
0 --
Ignore user-written auxiliary macro files, if any (default).
1 --
Use user-written auxiliary macro files (if they exist) as follows: Use
ADAPTMSH.MAC
instead of the default meshing command sequence. Use
ADAPTSOL.MAC
instead of the
default solution command sequence (
/SOLU
...
SOLVE
...
FINISH
).
Notes
ADAPT
invokes a predefined ANSYS macro for adaptive meshing and solution. The macro causes
repeated runs of the PREP7, SOLUTION, and POST1 phases of the ANSYS program with mesh
density refinements based upon the percentage error in energy norm. See the
ANSYS Advanced
Analysis Techniques Guide
for additional details. After the adaptive meshing process is complete, the
ADAPT
macro automatically turns element shape checking on (
SHPP
,ON).
A copy of the macro, called
UADAPT.MAC
, is available on the ANSYS distribution medium (system
dependent), and may be copied and modified by the user to suit a particular need. The modified file
should be given a suitable name (
cmd
.MAC) and run as described above with the
ADAPT
command
name replaced by your "
cmd
" name.
This command is also valid at the Begin level.
Menu Paths
See
ADAPT Menu Paths
in the
ANSYS Command Menu Path Listings
.
Prev
Up
Next
ADAMS
Home
ADD
mk:@MSITStore:K:\ansys61\docu\english\ansyshelp.chm::/Hlp_C_ADAPT.html
2002-11-21
Plik z chomika:
k22k83
Inne pliki z tego folderu:
mkb02-tarczao(1).avi
(3155 KB)
mkb07-Meshless1(1).pdf
(1422 KB)
mkb02-test189offset(1).avi
(659 KB)
mkb04(1).pdf
(339 KB)
mkb05(1).pdf
(244 KB)
Inne foldery tego chomika:
Zgłoś jeśli
naruszono regulamin