PS4 ZB4-501-UM3-UM4 Interface Converter h1371g.pdf

(631 KB) Pobierz
ZB4-501-UM3/-UM4, S40-AM-UM3/-UM4
Hardware, Configuration
and Functional Description
ZB4-501-UM3/-UM4 Interface Converter
S40-AM-UM3/-UM4 Application Module
Telecontrol Modules
05/00 AWB2700-1371GB
1st published 1999, edition date 08/99
2nd reprint 2000, edition date 05/00,
See list of modifications on page II
© Moeller GmbH, Bonn
Author: Peter Roersch
Editor: Thomas Kracht
Translator: Dominik Kreuzer
All brand and product names are trademarks or
registered trademarks of the owner concerned.
All rights reserved, including those of the transla-
tion.
No part of this manual may be reproduced in any
form (printed, photocopy, microfilm or any other
process) or processed, duplicated or distributed by
means of electronic systems without written
permission of Moeller GmbH, Bonn.
Subject to modifications.
645963295.005.png
Warning!
Dangerous electrical voltage!
Before commencing the installation
• Disconnect the power supply of the device.
• Ensure that devices cannot be accidentally
restarted.
• Verify isolation from the supply.
• Earth and short circuit.
• Cover or enclose neighbouring units that
are live.
• Follow the engineering instructions (AWA)
of the device concerned.
• Only suitably qualified personnel in accordance
with EN 50 110-1/-2 (VDE 0 105 Part 100) may
work on this device/system.
• Before installation and before touching the
device ensure that you are free of electrostatic
charge.
• The functional earth (FE) must be connected to
the protective earth (PE) or to the potential
equalisation. The system installer is responsible
for implementing this connection.
• Connecting cables and signal lines should be
installed so that inductive or capacitive interfe-
rence do not impair the automation functions.
• Install automation devices and related opera-
ting elements in such a way that they are well
protected against unintentional operation.
• Suitable safety hardware and software
measures should be implemented for the
I/O interface so that a line or wire breakage
on the signal side does not result in undefined
states in the automation devices.
• Ensure a reliable electrical isolation of the low
voltage for the 24 volt supply. Only use power
supply units complying with IEC 60 364-4-41
(VDE 0 100 Part 410) or HD 384.4.41 S2.
• Deviations of the mains voltage from the rated
value must not exceed the tolerance limits given
in the specifications, otherwise this may cause
malfunction and dangerous operation.
• Emergency stop devices complying with
IEC/EN 60 204-1 must be effective in all opera-
ting modes of the automation devices.
Unlatching the emergency-stop devices must
not cause restart.
• Devices that are designed for mounting in
housings or control cabinets must only be
operated and controlled after they have been
installed with the housing closed. Desktop or
portable units must only be operated and
controlled in enclosed housings.
• Measures should be taken to ensure the proper
restart of programs interrupted after a voltage
dip or failure. This should not cause dangerous
operating states even for a short time. If neces-
sary, emergency-stop devices should be imple-
mented.
• Wherever faults in the automation system may
cause damage to persons or property, external
measures must be implemented to ensure a safe
operating state in the event of a fault or
malfunction (for example, by means of separate
limit switches, mechanical interlocks etc.).
I
645963295.006.png 645963295.007.png
05/00 AWB2700-1371GB
List of modifications to the manual AWB2700-1371GB
Edition
date
Page
Description
New
Modi-
fica-
tion
Omit-
ted
05/00
Gene-
ral
Complete revision by the addition of
ZB4-501-UM4
x
II
645963295.008.png
05/00 AWB2700-1371GB
Contents
About This Manual
3
1 About the Modules
5
Purpose of the ZB4-501-UM3/-UM4
5
Hardware and software requirements
6
Setup
7
– ZB4-501-UM3
7
– ZB4-501-UM4
8
2 Engineering
9
ZB4-501-UM3/-UM4 in the Suconet K network
9
Power supply
10
– ZB4-501-UM3
10
– ZB4-501-UM4
10
Connections
11
– Suconet K connections
11
– RS232 port
11
Electromagnetic compatibility
14
– Earthing the data cables
16
3 Configuration
17
Configuring the software
17
Configuring the ZB4-501-UM4 hardware
17
– Activating/deactivating bus terminating resistors
19
– Setting the address
19
4in
21
Operating phase
21
Startup behaviour
21
Shutdown behaviour
21
5iis
23
LED function at startup
23
LED function during operation
23
Failure Codes
23
1
645963295.001.png
 
645963295.002.png
Contents
05/00 AWB2700-1371GB
6 Application Module
25
Software requirements
25
Installation
25
– S40-AM-UM3
25
– S40-AM-UM4
26
Function block UM3_COM
27
– Inputs and outputs
27
Function block UM4_COM
33
– Inputs and outputs
33
Data transfer
40
– Sending data
40
– Receiving data
41
Appendix 43
Receiving data 43
Technical data 44
– ZB4-501-UM3 44
– ZB4-501-UM4 45
– General EMC specifications for automation equipment 46
Dimensions
47
– ZB4-501-UM3
47
– ZB4-501-UM4
48
Index
49
2
645963295.003.png 645963295.004.png