DARWIN SWIRE-GW-DP h1590g.pdf

(815 KB) Pobierz
SWIRE-GW-DP
Connection
System
SmartWire
SWIRE-GW-DP
Hardware and
Function Description
11/06 AWB1251-1590GB
647042608.004.png
Rückenbreite festlegen! (1 Blatt = 0,106 mm)
All brand and product names are trademarks or registered
trademarks of the owner concerned.
1 st published 2006, edition date 11/06
© 2006 Moeller GmbH
Author: Wolfgang Nitschky
Editor: Heidrun Riege
Translator: David Long
All rights reserved, including those of the translation.
No part of this manual may be reproduced in any form
(printed, photocopy, microfilm or any other process) or
processed, duplicated or distributed by means of electronic
647042608.005.png 647042608.006.png
Warning!
Dangerous electrical voltage!
Before commencing the installation
• Disconnect the power supply of the device.
• Ensure that devices cannot be accidentally
restarted.
• Verify isolation from the supply.
• Earth and short circuit.
• Cover or enclose neighbouring units that
are live.
• Follow the engineering instructions (AWA)
of the device concerned.
• Only suitably qualified personnel in
accordance with EN 50110-1/-2
(VDE 0105 Part 100) may work on this
device/system.
• Before installation and before touching
the device ensure that you are free of
electrostatic charge.
• The functional earth (FE) must be
connected to the protective earth (PE) or
to the potential equalisation. The system
installer is responsible for implementing
this connection.
• Connecting cables and signal lines should
be installed so that inductive or capacitive
interference does not impair the
automation functions.
• Install automation devices and related
operating elements in such a way that they
are well protected against unintentional
operation.
• Suitable safety hardware and software
measures should be implemented for the
I/O interface so that a line or wire breakage
on the signal side does not result in
undefined states in the automation
devices.
• Ensure a reliable electrical isolation of the
low voltage for the 24 volt supply. Only
use power supply units complying with
IEC 60364-4-41 (VDE 0100 Part 410) or
HD 384.4.41 S2.
• Deviations of the mains voltage from the
rated value must not exceed the tolerance
limits given in the specifications, otherwise
this may cause malfunction and dangerous
operation.
•Emergency stop devices complying with
IEC/EN 60204-1 must be effective in all
operating modes of the automation
devices. Unlatching the emergency-stop
devices must not cause restart.
• Devices that are designed for mounting in
housings or control cabinets must only be
operated and controlled after they have
been installed with the housing closed.
Desktop or portable units must only be
operated and controlled in enclosed
housings.
I
647042608.007.png 647042608.001.png
• Measures should be taken to ensure the
proper restart of programs interrupted
after a voltage dip or failure. This should
not cause dangerous operating states even
for a short time. If necessary, emergency-
stop devices should be implemented.
• Wherever faults in the automation system
may cause damage to persons or property,
external measures must be implemented to
ensure a safe operating state in the event
of a fault or malfunction (for example, by
means of separate limit switches,
mechanical interlocks etc.).
II
647042608.002.png
11/06 AWB1251-1590GB
Contents
About this manual
3
Intended users
3
Additional device manuals
3
Reading convention
4
1 About the PROFIBUS-DP gateway
SWIRE-GW-DP
5
System overview
5
Design of the SWIRE-GW-DP
6
Description of function
6
2 Installation 9
Set PROFIBUS-DP station address 9
Connect SmartWire connection cable 10
Connect supply voltages 11
Connect PROFIBUS-DP 12
Connection assignment PROFIBUS-DP 13
Terminating resistors 14
EMC-conformant wiring of the network 14
Potential separations 15
Data transfer rates – automatic baud rate detection16
Maximum distances/bus cable lengths
16
3 Commissioning
19
Initial switch on
19
Meaning of the status LEDs
20
–Ready-LED
20
– U-Aux-LED
20
– SmartWire LED
21
– PROFIBUS LED
21
1
647042608.003.png
Zgłoś jeśli naruszono regulamin