east start T podłaczenie.pdf

(1174 KB) Pobierz
22_1000_32_88_07_EN_0706.indd
Installation instructions.
Comfort Timer
with 7-day preset capability.
EasyStart T
382746909.006.png
Contents
Introduction Page
• Please read first ..................................................................................................... 3
• General information / safety instructions ................................................................. 3
• ”Ventilate“ mode..................................................................................................... 3
• Purpose ................................................................................................................. 3
• Technical specifications .......................................................................................... 4
• Scope of supply ..................................................................................................... 4
• Additional parts (option).......................................................................................... 4
Installation instructions
• Installation .............................................................................................................. 5
– Install timer ....................................................................................................... 5
– Electrical connection .......................................................................................... 6
– Install room temperature sensor (optional).......................................................... 6
– Install external temperature sensor (optional)...................................................... 6
• Combine EasyStart T timer with EasyStart T timer.................................................. 7
Initial commissioning
• Perform initial commissioning ................................................................................. 8
– Apply operating voltage ..................................................................................... 8
– Automatic detection........................................................................................... 8
– Set the time and operating time ......................................................................... 8
– Configure system ........................................................................................ 9, 10
– Permissible unit combinations.......................................................................... 10
– Test timer......................................................................................................... 10
Miscellaneous
• Reset function ...................................................................................................... 11
What to do if …?
• Displays ............................................................................................................... 12
– ndiA display ..................................................................................................... 12
– Menu item A D does not appear in the menu bar .............................................. 12
– Menu item does not appear in the menu bar............................................... 12
Service .................................................................................................................... 12
Diagnosis
• Perform heater diagnosis .................................................................................... 13
• Display system configuration ............................................................................... 14
Circuit diagrams
• Parts list circuit diagrams .................................................................................... 15
• Assignment of the circuit diagrams to the different AIRTRONIC , AIRTRONIC M and
AIRTRONIC L heater models ................................................................................ 15
• Circuit diagrams (at the end of the installation instructions)
Declaration of conformity (at the end of the installation instructions)
2
382746909.007.png
Introduction
Please read first
Before you start to install the timer, please
ensure you carefully read through these
installation instructions.
These installation instructions contain
important information, which you require
to install the timer.
(Order No. 22 1000 32 07 00) must be
installed (see Circuit Diagrams, Item
3.1.17).
“Ventilate” mode is not possible in all
other heater models.
In the “ventilate” switch setting of
HYDRONIC water heaters the vehicle
blower is directly controlled by bypassing
heat mode and in AIRTRONIC air heaters
the heater’s blower is bypassed in the
same way.
General information / safety instruc-
tions
In ADR mode, immediate operation wit-
hout temperature display only is possible.
We recommend installing the temperature
sensor available as an option in order to
enable use of all the timer’s functions.
If the temperature sensor (optional) is
connected the heater start is automatical-
ly calculated for water heaters.
In air heaters the temperature sensor is
used for temperature display.
Please note!
“Ventilate” or “heat” mode must be se-
lected before switching on the heater.
• “Ventilate” mode is not provided for
upgraded independent heaters.
• If you have any further questions about
“ventilate” mode, please call the service
phone number (see page 12).
• The circuit diagrams are at the end of
these installation instructions.
Important!
Note and comply with the safety instruc-
tions and general information given in
the heater’s documentation and in the
EasyStart T operating instructions.
Purpose
The EasyStart T timer is used to switch
on / off and preset the switching-on time,
operating time and operating mode of the
heater and / or add-on unit installed in
the vehicle
„Ventilate“ mode
If the symbol is not displayed in the
menu bar, “ventilate” mode is only pos-
sible in the heater for the heater models
under certain prerequisites:
• With the water heaters HYDRONIC
(B / D 4 W S, B / D 5 W S, B / D 4
W SC and B / D 5 W SC): the “heat /
ventilate” switch (Order No. 22 1000
31 89 00) must be installed (see Circuit
Diagram, Item 3.1.9).
• With the air heaters AIRTRONIC /
AIRTRONIC M: the mini controller
Please note!
Improper use and use outside the spe-
cified area of use cancels all liability and
warranty.
3
382746909.008.png 382746909.009.png
Introduction
Technical specifications
Operating voltage: 12 V / 24 V
Dimensions: 36 x 51 x 10.5 mm
Operating temperature: –40 °C to +80 °C
LCD: readability is ensured from –20 °C
to +60 °C.
Please note!
At temperatures below –10 °C the display
becomes sluggish, i.e. the flashing se-
quence is slower.
Scope of supply
1 12 V / 24 V timer
1 Cap
1 Fixingscrew
1 Base
1 Flat connector housing
9 Junior Power Timer push on sleeve
1 Push on sleeve housing
2 Lockingclasps
1 Drillingtemplate
Additional parts (option)
– Room temperature sensor
(Order No.: 22 1000 32 49 00)
– External temperature sensor
(Order No.: 25 1482 89 41 00)
– “ON / OFF” button
(Order No.: 22 1000 32 84 00)
– Console
(Order No.: 22 1000 51 32 00)
4
382746909.001.png
Installation instructions
Installation
Install timer
Install the timer in a suitable place on the
dashboard within the driver‘s line of vision
and connect according to the sketch
and circuit diagrams at the end of this
documentation.
• Use the self-adhesive drilling template
provided to position and drill the holes.
Remove the drilling template when you
have finished drilling.
• If necessary, the foam pad base can be
used to balance out any unevenness.
To do this, pull off the protective plastic
sheet and stick the base onto the timer.
• Feed the heater lead harness through
the ø 8 mm drill hole.
• Preassemble the timer with expansion
plug in the ø 6.5 mm drill hole.
• If the foam pad base is used, pull off the
second protective plastic sheet too.
• Push or screw the fixing screw into the
expansion bolt to fasten the timer .
• Pull off the protective plastic sheet on
the cap and stick in the cap.
• Fix the flat connector of the timer lead
harness in the 9-pin flat connector
housing.
• Push in the locking clasp at the flat
connector housing.
Installation
10
11
1
9
1 2
12
2
8
7
3
6
4
5
1 Timer
2 Fixingscrew
with cap
3 Lead harness to heater
4 Room temperature sensor (optional)
5 Self-tapping screw C2.9 x 19
(1x, optional)
6 Push on sleeves (9x)
7 Push on sleeve housing
8 Flat connector housing
9 Timer lead harness
10 Drilling template
11 Foam pad base
12 Locking clasps
Please note!
• Only install the timer inside the vehicle.
• When selecting the installation position,
ensure the display is clearly visible, if
necessary use the console (optional).
5
382746909.002.png 382746909.003.png 382746909.004.png 382746909.005.png
Zgłoś jeśli naruszono regulamin