panel MFD.pdf

(6425 KB) Pobierz
Multi-Function Display MFD-Titan
Operating Instructions
11/10 MN05002001Z-EN
Multi-Function Display
MFD-Titan
455486727.002.png 455486727.003.png
All brand and product names are trademarks or registe-
red trademarks of the owner concerned.
Emergency On Call Service
Please call your local representative:
http://www.eaton.com/moeller/aftersales
or
Hotline of the After Sales Service:
+49 (0) 180 5 223822 (de, en)
AfterSalesEGBonn@eaton.com
Original Operating Instructions
The German-language edition of this document is the
original operating manual.
Translation of the original operating manual
All editions of this document other than those in Ger-
man language are translations of the original German
manual.
1 st published 2003, edition date 06/03,
2 nd edition 06/04,
3 rd edition 05/10,
4 th edition 11/10
See revision protocol in the “About this manual“
chapter
© 2003 by Eaton Industries GmbH, 53105 Bonn
Production: DHW
Translation: globaldocs GmbH
All rights reserved, including those of the translation.
No part of this manual may be reproduced in any form
(printed, photocopy, microfilm or any other process) or
processed, duplicated or distributed by means of
electronic systems without written permission of
Eaton Industries GmbH, Bonn.
Subject to alteration without notice.
455486727.004.png
Danger!
Dangerous electrical voltage!
Before commencing the installation
• Disconnect the power supply of the device.
• Ensure a reliable electrical isolation of the low voltage for the
24 volt supply. Only use power supply units complying with
IEC 60 364-4-41 (VDE 0 100 Part 410) or HD 384.4.41 S2.
• Ensure that devices cannot be accidentally restarted.
• Verify isolation from the supply.
• Deviations of the mains voltage from the rated value must
not exceed the tolerance limits given in the specifications,
otherwise this may cause malfunction and dangerous
operation.
• Earth and short circuit.
• Cover or enclose neighbouring units that are live.
• Follow the engineering instructions (AWA) of the
device concerned.
• Emergency stop devices complying with IEC/EN 60 204-1 must
be effective in all operating modes of the automation devices.
Unlatching the emergency-stop devices must not cause restart.
• Only suitably qualified personnel in accordance with
EN 50110-1/-2 (VDE 0105 Part 100) may work on
this device/system.
• Devices that are designed for mounting in housings or control
cabinets must only be operated and controlled after they have
been installed with the housing closed. Desktop or portable
units must only be operated and controlled in enclosed
housings.
• Before installation and before touching the device ensure
that you are free of electrostatic charge.
• The functional earth (FE) must be connected to the protective
earth (PE) or to the potential equalisation. The system installer
is responsible for implementing this connection.
• Measures should be taken to ensure the proper restart of
programs interrupted after a voltage dip or failure. This should
not cause dangerous operating states even for a short time.
If necessary, emergency-stop devices should be implemented.
• Connecting cables and signal lines should be installed so
that inductive or capacitive interference does not impair the
automation functions.
• Wherever faults in the automation system may cause
damage to persons or property, external measures must be
implemented to ensure a safe operating state in the event of
a fault or malfunction (for example, by means of separate limit
switches, mechanical interlocks etc.).
• Install automation devices and related operating elements in
such a way that they are well protected against unintentional
operation.
• Suitable safety hardware and software measures should be
implemented for the I/O interface so that a line or wire
breakage on the signal side does not result in undefined
states in the automation devices.
I
455486727.005.png 455486727.001.png
 
II
Contents
0
About This Manual..................................................................... 13
0.1
List of revisions ............................................................................ 13
0.2
Target group................................................................................. 14
0.3
Exclusion of liability ...................................................................... 14
0.4
Device designation....................................................................... 16
0.5
Writing conventions ..................................................................... 17
1 MFD ............................................................................................. 19
1.1 Proper use.................................................................................... 19
1.2 Overview of functions.................................................................. 19
1.3 Versions ....................................................................................... 21
1.3.1 Display and operating unit............................................................ 21
1.3.2 Power supply/CPU module .......................................................... 21
1.3.3 I/O module digital/analog.............................................................. 22
1.3.4 I/O module with temperature measuring..................................... 22
1.3.5 LED display .................................................................................. 23
1.3.6 Key to part numbers MFD............................................................ 24
1.4 Possible combinations of basic devices and expansion units ...... 24
1.5 Extended functionality of MFD-CP10... compared to MFD-
CP8... ........................................................................................... 27
1.6 MFD operation ............................................................................. 28
1.6.1 Key Pad ........................................................................................ 28
1.6.2 Selecting menus and entering values .......................................... 28
1.6.3 Status display for the MFD basic device...................................... 29
1.6.4 Status display for the local expansion module ............................. 31
1.6.5 Status display additional information............................................ 31
1.6.6 Menu structure ............................................................................ 32
1.6.7 Choosing the main and system menu ......................................... 32
1.6.8 Main menu without activated password protection..................... 33
1.6.9 Main menu with activated password protection.......................... 33
1.6.10 System menu............................................................................... 34
1.6.11 Selecting or toggling between menu items ................................. 36
1.6.12 Cursor display............................................................................... 36
1.6.13 Setting values............................................................................... 37
Handbuch 11/10 MN05002001Z-DE www.eaton.com