S7-300_cp343-1_Advanced_e.pdf

(415 KB) Pobierz
S7-CPs for Industrial Ethernet
SIMATIC NET
S7-CPs for Industrial Ethernet
Manual Part B3A
CP 343-1 Advanced
6GK7 343−1GX21−0XE0
Version 1 or higher (Firmware Version V1.0)
for SIMATIC S7−300 / C7−300
C−PLUG
LED displays
Mode selector
TP port:
8-pin RJ-45 jack
Release 02/2006
C79000−G8976−C202−03
43517204.009.png 43517204.010.png 43517204.011.png 43517204.012.png 43517204.001.png
 
Notes on the Product
Notes on the Product
Product Names
This description contains information on the following product
CP 343−1 Advanced
Note
In this document, the term CP or CP 343−1 is used instead of the full product
name.
Printed Product Information Supplied with the Product
Note
All the notices in the Product Information Bulletin shipped with this device are
valid and must be adhered to.
Compatibility with the Previous Version
Note
Due to the increased functionality and restrictions, pay particular attention to
the notes in Chapter 9 of this manual.
Address label: Unique MAC address preset for the CP
The CP ships with a factory-set MAC address.
To ensure a unique address assignment, we recommend that you use this factory
set MAC address when configuring the module!
B3A−2
CP 343-1 Advancedfor Industrial Ethernet / Manual Part B3A
Release 02/2006
C79000−G8976−C202−03
43517204.002.png 43517204.003.png
Contents
Contents
Contents − Part A
Ethernet CPs − General Information
. . . . . . . . . . . . . . . . . . .
See General Part
Note
Please remember that Part A of the manual also belongs to the description of the
CP. Among other things, it contains explanations of the safety notices, the
references to literature, and general information that applies to all S7 CPs for
Industrial Ethernet.
The version of the General belonging to this Part B of the manual is version
1/2005.
You can also obtain the current Part A from the Internet:
Contesnts − Part B3A
1 Properties / Services
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−5
2 Requirements for Use
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−9
3 Installation and Commissioning
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−11
3.1
Procedure / Steps
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−11
3.2
C−PLUG (Configuration Plug)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−14
3.3
Module Replacement without PG
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−16
4 Displays and Mode Selector
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−18
5 Performance Data
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−21
5.1
General Characteristic Data
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−21
5.2
Characteristic Data for S7 Communication
. . . . . . . . . . . . . . . . . . . . . . .
B3A−21
5.3
Characteristics of the SEND/RECEIVE Interface
. . . . . . . . . . . . . . . . .
B3A−23
5.4
Characteristic Data for PROFINET IO
. . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−24
5.5
Characteristic Data for PROFINET CBA
. . . . . . . . . . . . . . . . . . . . . . . . .
B3A−25
5.6
Characteristic Data HTTP and FTP Operation
. . . . . . . . . . . . . . . . . . . .
B3A−29
5.7
Characteristic Data of TCP Connections for HTTP
. . . . . . . . . . . . . . . .
B3A−29
5.8
Characteristic Data for the Use of Java Applets
. . . . . . . . . . . . . . . . . . .
B3A−30
5.9
Characteristics of the C−PLUG
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−30
5.10
Memory Organization
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−31
CP 343-1 Advanced for Industrial Ethernet / Manual Part B3A
Release 02/2006
C79000−G8976−C202−03
B3A−3
43517204.004.png 43517204.005.png 43517204.006.png
Contents
5.10.1 Memory Distribution
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−31
5.10.2 File Systems
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−32
6 Using the CP 343−1 for PROFINET IO
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−34
6.1
Configuring the CP 343−1 as a PROFINET IO Controller
. . . . . . . . . .
B3A−34
6.2
Operating PROFINET IO Alongside other Services
. . . . . . . . . . . . . . .
B3A−35
6.3
PROFINET IO Interface in the User Program: FCs
. . . . . . . . . . . . . . . .
B3A−36
7 Using the CP 343−1 with PROFINET CBA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−37
7.1
CBA Interface in the User Program with FB88
. . . . . . . . . . . . . . . . . . . .
B3A−37
7.2
Preparing for Configuration with STEP 7
. . . . . . . . . . . . . . . . . . . . . . . . .
B3A−37
7.3
PROFINET Configuration with SIMATIC iMap
. . . . . . . . . . . . . . . . . . . .
B3A−38
7.4
Using PROFINET CBA Communication and Standard
Communication at the same Time
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−41
8 The CP 343-1 Advanced as Web Server: HTML Process Control
. . . . . . . . . . .
B3A−43
9 Compatibility with the Predecessor Product
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−44
9.1
Extended Functionality
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−44
9.2
Replacing Older Modules / Replacing Faulty Modules
. . . . . . . . . . . . .
B3A−45
10 Further Notes on Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−47
10.1
Memory Reset
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−47
10.2
Working with Fast Ethernet − automatic switchover
. . . . . . . . . . . . . . .
B3A−51
10.3
SNMP Agent
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−52
10.4
Possible Security Gaps on Standard IT Interfaces /
Preventing Illegal Access
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−53
10.5
Influence of MPI on Connections via Industrial Ethernet
. . . . . . . . . . .
B3A−54
10.6
Special Features of IP Configuration
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−54
10.7
Reserved Port Numbers
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−54
10.8
Restart after Detection of a Duplicate IP Address in the Network
. . . .
B3A−55
10.9
Obtaining the IP Address over DHCP − CP STOP on Expiry of the
Lease
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−55
10.10
IP Access Protection over the IP Access Control List in PROFINET IO B3A−56
10.11
Additional Condition Codes in the Diagnostic Buffer
. . . . . . . . . . . . . . .
B3A−56
10.12
Setting the CPU Time of Day by the CP
. . . . . . . . . . . . . . . . . . . . . . . . .
B3A−56
10.13
IP Access protection − LOG File in the File System
. . . . . . . . . . . . . . .
B3A−57
10.14
Other information available about the CP
. . . . . . . . . . . . . . . . . . . . . . . .
B3A−57
11 How to Load New Firmware
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−58
12 Technical Specifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3A−60
B3A−4
CP 343-1 Advancedfor Industrial Ethernet / Manual Part B3A
Release 02/2006
C79000−G8976−C202−03
43517204.007.png
1 Properties / Services
1 Properties / Services
Application
The CP 343−1 communications processor is designed for operation in an S7-300
programmable logic controller. It allows the S7-300 to be attached to Industrial
Ethernet.
Services
The CP 343-1 supports the following communication services:
PROFINET IO Controller
PROFINET IO allows direct access to IO devices over Ind. Ethernet.
PROFINET CBA
Use of a SIMATIC S7-300 for Component based Automation based on the new
PROFINET Standard of the PNO. This standard allows:
− Component technology in automation
− Graphic configuration of communication between intelligent devices instead
of laborious programming
− Vendor−independent, plant−wide engineering
Component based Automation allows access to the variables of PROFINET
components from all standard PC applications with the OPC client interface, for
example, visualization systems. Over the OPC server, objects can be selected
directly from a variable selection list of the selected PROFINET component.
S7 communication and PG/OP communication
− PG functions (including routing)
− Operator control and monitoring functions (HMI)
multiplexing TD/OP connections
− Client and server for data exchange using communication blocks 1 ) on S7
connections configured at both ends
− Server for data exchange on S7 connections configured at one end only
without communication blocks on the S7-300 / C7-300 station
1)
Blocks for S7 communication (see also STEP 7 online help or manual
“System Software for S7-300/400 System and Standard Functions”) :
BSEND
FB12
BRCV
FB13
PUT
FB14
GET
FB15
USEND
FB8
URCV
FB9
C_CNTRL
FC62
CP 343-1 Advanced for Industrial Ethernet / Manual Part B3A
Release 02/2006
C79000−G8976−C202−03
B3A−5
43517204.008.png
 
Zgłoś jeśli naruszono regulamin