S7-300_CP343-1_Lean_e.pdf

(618 KB) Pobierz
S7-CPs for Industrial Ethernet
SIMATIC NET
S7-CPs for Industrial Ethernet
Manual Part B3L
CP 343-1 Lean
6GK7 343−1CX10−0XE0
as of hardware version 2, as of firmware version V2.0
for SIMATIC S7−300 / C7−300
LED displays
TP port:
2 x 8−pin RJ−45 socket
(beneath the front panel)
X = Placeholder for hardware
version
Release 03/2007
C79000-G8976-C198-04
43517255.006.png 43517255.007.png
Notes on the Product
Notes on the Product
Product Names
This description contains information on the following product
CP 343−1 Lean
Order number 6GK7 343−1CX10−0XE0
as of hardware version 2 and firmware version V2.0
for SIMATIC S7−300 / C7−300
Note
In this document, the term CP is used instead of the full product name.
Printed Product Information Supplied with the Product
Note
All the notices in the Product Information Bulletin shipped with this device must
be adhered to.
Compatibility with the Previous Version
Note
Due to the increased functionality and restrictions, pay particular attention to
the notes in Chapter 8 of this manual.
Address label: Unique MAC address preset for the CP
The CP ships with a factory-set MAC address.
To ensure a unique address assignment, we recommend that you use this factory
set MAC address when configuring the module!
B3L−2
CP 343-1 Lean for Industrial Ethernet / Manual Part B3L
Release 03/2007
C79000-G8976-C198-04
43517255.008.png 43517255.009.png
Contents
Contents
Contents − Part A
Ethernet CPs − General information
. . . . . . . . . . . . . . . . . . .
see general part
Note
Please remember that Part A of the device manual also belongs to the description
of the CP. Among other things, it contains explanations of the safety notices and
general information that applies to all S7 CPs for Industrial Ethernet.
You will find the references in this Part B of the manual /.../ in the Appendix of the
general Part A of the manual.
The following version of the manual Part A of the manual belongs to this version of
Part B: Release 01/2007
You can download the general Part from the Internet:
Contents − Part B3L
1 Properties / Services
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−5
2 Requirements for Use
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−8
3 Installation and Commissioning
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−11
3.1
Procedure / Steps
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−11
4 Displays
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−14
5 Performance Data
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−17
5.1
Number of Possible Connections over Ethernet
. . . . . . . . . . . . . . . . . . .
B3L−17
5.2
Characteristic Data for S7 Communication
. . . . . . . . . . . . . . . . . . . . . . .
B3L−17
5.3
Characteristics of the SEND/RECEIVE Interface
. . . . . . . . . . . . . . . . .
B3L−18
5.4
Characteristic Data for PROFINET IO
. . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−19
6 Configuring and Programming the CP as a PROFINET IO Device
. . . . . . . . . .
B3L−20
6.1
Overview of the Preparatory Steps
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−20
6.2
Principle of Data Exchange over PROFINET IO
. . . . . . . . . . . . . . . . . .
B3L−21
6.3
Configuration
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−22
6.3.1
Installing the CP and Specifying it as PROFINET IO Device
. . . . . . . .
B3L−22
6.3.2
Assigning the PROFINET IO Device to a PROFINET IO Controller
. .
B3L−24
6.4
Programming
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−27
6.4.1
Interface for Programming on the PROFINET IO Device
. . . . . . . . . . .
B3L−27
CP 343-1 Lean for Industrial Ethernet / Manual Part B3L
Release 03/2007
C79000-G8976-C198-04
B3L−3
43517255.001.png 43517255.002.png 43517255.003.png
Contents
6.4.2
Initialization and Configuration
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−28
6.5
Example of Configuration and Programming
. . . . . . . . . . . . . . . . . . . . .
B3L−30
7 Web Diagnostics
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−33
7.1
Requirements and Use
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−33
7.2
Diagnostics Pages of the CP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−34
7.2.1
Start Page
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−35
7.2.2
Identification
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−36
7.2.3
Rack Configuration
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−37
7.2.4
Diagnostic Buffer
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−39
7.2.5
Industrial Ethernet
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−40
7.2.6
PROFINET IO
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−42
8 Compatibility with Predecessor Products
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−44
8.1
Extended Functionality
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−44
8.2
Replacing Older Modules / Replacing Faulty Modules
. . . . . . . . . . . . .
B3L−44
9 Further Notes on Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−46
9.1
Memory Reset
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−46
9.2
Working with Fast Ethernet − automatic switchover
. . . . . . . . . . . . . . .
B3L−47
9.3
SNMP Agent
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−49
9.4
Possible Security Gaps on Standard IT Interfaces / Preventing
Illegal Access
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−50
9.5
Influence of MPI on Connections via Industrial Ethernet
. . . . . . . . . . .
B3L−50
9.6
Special Features of IP Configuration
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−51
9.7
Reserved Port Numbers
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−51
9.8
Restart after Detection of a Duplicate IP Address in the Network
. . . .
B3L−52
9.9
Obtaining the IP Address over DHCP − CP STOP on Expiry of
the Lease
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−52
9.10
Other information available about the CP
. . . . . . . . . . . . . . . . . . . . . . . .
B3L−52
10 How to Load New Firmware
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−53
11 Technical Specifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3L−54
B3L−4
CP 343-1 Lean for Industrial Ethernet / Manual Part B3L
Release 03/2007
C79000-G8976-C198-04
43517255.004.png
1 Properties / Services
1 Properties / Services
Application
The CP 343−1 Lean communications processor is designed for operation in a
SIMATIC S7-300 programmable logic controller. It allows attachment of the
S7−300 to Industrial Ethernet and supports PROFINET IO.
A 2-port switch with autocrossing, autonegotiation and autosensing was integrated
in the CP for simple integration in a line or for attaching a further Ethernet device.
Services
The CP supports the following communication services:
PROFINET IO device
Integration of the SIMATIC S7−300 programmable controller over the CP as
intelligent PROFINET IO device.
S7 communication and PG/OP communication
− PG functions (including routing)
− Operator control and monitoring functions (HMI)
− Server for data exchange on S7 connections configured at one end only
without communication blocks on the S7-300 / C7-300 station
S5 compatible communication with
− SEND/RECEIVE interface over ISO-on-TCP, TCP and UDP connections
− Multicast over UDP connection
The multicast mode is made possible by selecting a suitable IP address
when configuring connections.
− FETCH/WRITE services (server; corresponding to S5 protocol) via
ISO-on-TCP connections and TCP connections;
The addressing mode can be configured for FETCH/WRITE access as the
S7 or S5 addressing mode.
− LOCK/UNLOCK with FETCH/WRITE services;
CP 343-1 Lean for Industrial Ethernet / Manual Part B3L
Release 03/2007
C79000-G8976-C198-04
B3L−5
43517255.005.png