Daewoo CP-375.pdf

(2366 KB) Pobierz
5
194734654.006.png
Specifications
CRT A34JLL90X01,A34EAC01X06,A34EFU13X01
(OEC) (PHILIPS) (POLKOLOR)
System C14M7E : PAL-B/G for West Europe (Non-TXT)
C14M7F : PAL-B/G, SECAM-L for France (Non-TXT)
C14T7B : PAL- I for U.K (TXT)
C14M7B : PAL- I for U.K (Non-TXT)
C14T7L : PAL - I/I for Ireland (TXT)
C14M7L : PAL - I/I for Ireland (Non-TXT)
Main Voltage 230V AC, 50Hz
Power Consumption Stand-by mode : 8 Watts
Normal operating mode : 39Watts
Sound output
1.5 Watts, 10 % THD at RF 60 % mod.
Speaker
3W 16 ohm x 1 EA
Antenna
75 ohm unbalanced input
Impedance
Tuning system
VS( voltage synthesis ) tuning
Tuner
3303KHC (C14M7E, C14M7F, C14T7L, C14M7L)
BAND I : CH2 - CH4
BAND III : CH5 - CH12
CABLE BAND : S1’ - S3’ , S1 - S20
HYPER BAND : S21 - S41
BAND IV, V : CH21 - CH69
DT2-IV17D (C14T7B, C14M7B )
BAND IV, V : CH21 - CH69
Number of
70 programs
program
Aux. Terminal
21 pin EURO-SCART jack
( AV input, TV output, RGB input, S-VHS input )
RCA type AV input jack
Headphone jack (3.5 mm )
Remote controller
RM-01A01 with 2 “AA” type batteries
Teletext
8 pages memory TOP & FLOF
(option)
: English, German/Dutch/Flemish, French, Italian,
Spanish/Portuguese, Swedish/Finnish/Danish, Czech/Slovak
OSD language
-TXT Model : English,French,German,Italian,Spanish
-Non-TXT Model : English,French,German,Italian,Spanish, Russian
1
194734654.007.png
Safety Instruction
WARNING: Only competent service personnel may carry out work involving the testing or repair of
this equipment.
X-RAY RADIATION PRECAUTION
1. Excessive high voltage can produce potentially
hazardous X-RAY RADIATION.To avoid such
hazards, the high voltage must not exceed the
specified limit. The nominal value of the high
voltage of this receiver is 22-23 at max beam
current. The high voltage must not, under any
circumstances, exceed 27.5 .
Each time a receiver requires servicing, the high
voltage should be checked. It is important to use
an accurate and reliable high voltage meter.
2. The only source of X-RAY Radiation in this TV
receiver is the picture tube.For continued X-RAY
RADIATION protection,the replacement tube
must be exactly the same type tube as specified
in the parts list.
SAFETY PRECAUTION
1. Potentials of high voltage are present when this
receiver is operating. Operation of the receiver
outside the cabinet or with the back board
removed involves a shock hazard from the
receiver.
1) Servicing should not be attempted by anyone
who is not thoroughly familiar with the
precautions necessary when working on high-
voltage equipment.
2) Discharge the high potential of the picture tube
before handling the tube. The picture tube is
highly evacuated and if broken, glass
fragments will be violently expelled.
2. If any Fuse in this TV receiver is blown, replace it
with the FUSE specified in the Replacement
Parts List.
3. When replacing a high wattage resistor(oxide
metal film resistor)in circuit board, keep the
resistor 10mm away from circuit board.
4. Keep wires away from high voltage or high
temperature components.
5. This receiver must operate under AC230 volts,
50Hz. NEVER connect to DC supply or any other
power or frequency.
PRODUCT SAFETY NOTICE
Many electrical and mechanical parts in this have
special safety-related characteristics. These
characteristics are often passed unnoticed by a
visual inspection and the X-RAY RADIATION
protection afforded by them cannot necessarily be
obtained by using replacement components rated
for higher voltage,wattage,etc. Replacement parts
which have these special safety characteristics are
identified in this manual and its supplements,
electrical components having such features are
identified by designated symbol on the parts list.
Before replacing any of these components, read the
parts list in this manual carefully. The use of
substitute replacement parts which do not have the
same safety characteristics as specified in the parts
list may create X-RAY Radiation.
3
194734654.008.png
Circuit block Diagram
4
194734654.009.png 194734654.001.png
Alignment Instructions
Remark: A service remocon(R-30SVC) is needed to align the set.
1. AFT
5 dBuV
- System = PAL / SECAM - B/G,
2) Connect the Signal Generator RF Output to P101 (Tuner IF Output).
There must be no signal input to the tuner.
3) Press the “AFT” KEY and wait until the TV screen display “AFT OK”.
°
1.2 Standard SECAM-L’ (France VHF-Low)
Above mentioned “1.1” adjustment has to be done in advance.
1) Set a Signal Generator with
- RF FREQUENCY = 34.2 MHz,
- RF OUTPUT LEVEL = 80
°
5 dBuV
- System = SECAM - L’
2) Connect the Signal Generator RF Output to P101 (Tuner IF Output).
There must be no signal input to the tuner.
3) Press the “L’ AFT” KEY and wait until the TV screen display “L AFT OK”.
2 dBuV .
2) Connect a OSCILLOSCOPE PROBE to P101 (TUNER AGC INPUT).
3) Adjust AGC UP/DOWN KEY the voltage drop 1V dc over below its maximum voltage.
°
5 dBuV
- PAL CROSSHATCH
( without SOUND CARRIER )
2) Connect a OSCILLOSCOPE
( Bandwidth 100MHz ) PROBE
to P101 (TUNER IF OUTPUT).
3) Use AGC UP/DOWN KEY to obtain
an envelop amplitude 200 + 50 mVp-p.
°
3. SCREEN
1) Apply a COLOR BAR pattern signal.
2) Set the CONTRAST, BRIGHTNESS
Black level
to MAX, COLOR to MIN.
3) Set the R,G,B LEVEL to CENTER (31/63)
with R,G,B UP/DOWN KEY.
130
°
5Vdc
4) Connect a OSCILLOSCOPE PROBE
to P906 ( CRT CATHOD R, G, B ).
5) Adjust the SCREEN VOLUME on FBT
such that the highest black level voltage,
GND
130
°
5Vdc.
5
1.1 Standard B/G,D/K,I and L
1) Set a Signal Generator with
- RF FREQUENCY = 38.9 MHz,
- RF OUTPUT LEVEL = 80
2. AGC
1) Set a Pattern Generator with RF LEVEL 63
Alternative Method
1) Set a Pattern Generator with
- RF LEVEL 80
194734654.002.png 194734654.003.png 194734654.004.png 194734654.005.png
Zgłoś jeśli naruszono regulamin