Rodinal.PDF

(18 KB) Pobierz
Rodinal.PDF
RODINAL AND RODINAL SPECIAL PROCESS TIMES
DEVELOPER
RODINAL 1 + 25
RODINAL 1 + 50
RODINAL 1 + 100
RODINAL 1 + 100
RODINAL SP ECIAL
FILM
TANK DRUM
ISO
TANK DRUM
ISO
TANK
ISO
CONT TANK
ISO
CONT TANK DRUM
ISO
AGFA
APX 25
6
4
20/14
10
9
25/15
15
16/13
0.55
20
20/14
0.60
4
3
25/15
APX 100
8
7
100/21
17
14
125/22
15
64/19
0.45
20
100/21
0.50
4
3
125/22
APX 400
7
5
320/26
11
9
320/26
15
200/24
0.50
20
250/25
0.50
4.5
4
400/27
ILFORD
PAN F
5
4
50/18
15
13
50/18
3.5
3
64/19
PAN F PLUS
5
4
50/18
11
9
50/18
15
25/15
0.60
20
25/15
0.60
3
2.7
32/16
FP4
5
4
125/22
13
11
125/22
5
4
125/22
FP4 PLUS
5
4
125/22
13
11
125/22
15
64/19
0.45
20
125/22
0.50
4
3.5
160/23
HP5 PLUS
8
7
320/26
NR
NR
15
100/21
0.45
20
160/24
0.50
4
3.5
320/26
DELTA 100
5
4
80/20
10
9
80/20
15
64/19
0.62
20
80/20
0.68
3
2.7
64/19
DELTA 400
8
7
250/25
18
15
250/25
15
125/22
0.50
20
160/24
0.60
8
6.5
320/26
DELTA 3200**
8
7
3200/36
18
15
3200/36
SFX
5
4
200/24
9.5
8
200/24
KODAK
PANATOMIC X
5
4
64/19
11
9
50/18
3.5
3
64/19
PLUS X
6
4
125/22
13
11
125/22
5
4
125/22
TRI X
7
5
500/28
12
10
400/27
15
250/25
0.65
20
400/27
0.65
6
4.5
320/26
T MAX 100
5.5
4.5
50/18
12
10
64/19
15
64/19
0.62
20
80/20
0.68
5
4
50/18
T MAX 400
5
4
320/26
10
9
320/26
15
200/24
0.50
20
160/24
0.60
5
4
400/27
T MAX 3200
8
7
3200/36
16
13
3200/26
6
4.5
3200/26
RECORDING 2475
4.5
3.5
640/29
10
9
640/29
TECH PAN
7 – 9
INFRA RED
5.5
FUJI
NEOPAN 100
7
5
100/21
16
14
100/21
NEOPAN 400
6
4
250/25
11
9
320/26
15
200/24
0.55
20
250/25
0.65
4
3.5
320/26
NEOPAN 1600
5
4
640/29
8
7
640/29
15
250/25
0.60
20
400/27
0.70
4
3.5
800/30
KONICA
KONICAPAN 100 5 4 100/21 13 11 100/21
PROCESS NOTES: All times are in minutes and are at 20 degrees Celsius. The recommended agitation is as follows: in tanks, constant for the first 30 seconds and then 5 secs every 30
seconds. In drums, choose a rotation speed above 30 RPM (changing direction if possible). The average contrast is 0.65 unless otherwise stated. The ISO recommendations should be
followed if possible. ** The times for Ilford Delta 3200 have not been tested and are a guide only.
The RODINAL 1 + 100 times are only recommended for use in hand tanks. There should be a minimum of 250 ml’s of solution for each film in the tank.
207706534.013.png 207706534.014.png 207706534.015.png 207706534.016.png 207706534.001.png 207706534.002.png 207706534.003.png 207706534.004.png 207706534.005.png 207706534.006.png 207706534.007.png 207706534.008.png 207706534.009.png 207706534.010.png 207706534.011.png 207706534.012.png