Appendix FB-DAP Simple Human Machine Interface
In addition to timer, counter, register, and contact data access function, the date setter of FB-DAP can connect to
many others for alarm message display, self-defined buttons, wireless card reading, and the like simple human-machine
(HM) functions.
FB-DAP Simple HM
Model
FB-DAP-A(R)
FB-DAP-B(R)
Spec.
Display
LCD (English version), 2-line
×
16-character, LED backlight
Button
20-key (4
×
5)
Wireless Card reading
−
AR and
−
BR only
,
distance 12
~
18cm
Power supply
5V
24V
Current consumption
100mA (120mA)
41mA (48mA)
Com. Interface
HCMOS
RS-485
Service points
connected
Single set
Max. 16-set connected
PLC Com. Port
connected
port 0
port 0,1,2 (In which port 0 and 1
needed to be converted as RS-485)
General feature
Timing/counting
、
register
、
contact access(write protected for each)
Special feature
Alarm
、
message display
、
self-definition of special speed keys
Card writing feature
Order for machine types with special numbers to us is required
※
PLC’s MA
、
MU type machines can be connected to FB-DAP-B(R) only through FB-485 switch.
Wirelesssensingcard
Model
CARD-1
CARD-2
Spec.
Memory
64bits with Cyclic Redundancy Check (CRC) on data
Operation temp.
−
25°C
~
50°C (conforming to ISO7810)
Power supply
Battery not required (power supplied from wireless electric waves released by an
−
AR/
−
BR card-reading module)
Sensing distance
12cm
~
18cm(from FB-DAP front)
Number of writing
unwritable(uncopiable
,
exclusively)
10000 times at least
Size (mm)
86
×
54
×
13
Weight (Gram)
12
Appendix -1
1.1
Profile
112
7
98
7
16
外徑
4
ψ×
4
埋螺帽
6.5
8
14.8
FB-DAP
DATA ACCESS PANEL
30
FATEK
1.5
X
+
ON / OFF
FUN
148
148
T
7
8
9
CLEAR
118.45
Y
E
F
ADR / DOC
C
4
5
6
M
A
B
DEC / HEX
D
1
2
3
S
W
CV / PV
22.43
R
0
SHIFT
ENTER
14.75
102.5
12
17.6
4.75
9.9
1.2
Important points before operation
1
、
FB-DAP possesses a function to return to the operation mode (general data setter and self-definition 8/16
speed keys) before power failure and each DAP can be place in a different mode when connecting many sets.
2
、
When operating FB-DAP
,
D2944
~
D3071 register of PLC will be used as the systematic architecture zone (in
which data set by all the FUN functions can be stored except item 11) , the user shall avoid this zone.
3
、
Any communication port, once converted to a RS-485 interface (port 2 is itself a RS-485 interface), can be
connected to a maximum of 16 FB-DAP-B(R) sets.
PLC port0
(HCMOS)
B
FB-485P0 switch head
B
RS-485 interface
Only thus so the FB-DAPB (R) can
be connected to.
B
FB-485 switch
B
RS-485 interface
PLC port1
(RS-232)
4
、
When PLC is connected with FB-DAP-B(R)
,
the service point numbers of PLC are limited to a range of 1~32.
5
、
Parameters for the connection between PLC and FB-DAP-B(R)(DAP automatic detection Baud Rate 9600 /
19200 / 38400)
port0
、
1
、
2
:
9600 / 19200 / 38400
、
Even
、
7Data bits
、
1Stop bit
ex
:
R4158=5521H, i.e. port2 being 9600
;
R4158=5523H, i.e. port2 being 38400.
6
、
When many sets of DAP are connected, if any two or more have the same service point number, then DAP will
request for number change, which can be done by only entering
〝
new DAP
〞即可。
7
、
The transmission line of the RS-485 interface must use a twisted pair with a shielded cover on the outer layer.
Please refer to chapter 12-5 in the Operation Manual II for other important points.
8
、
The scanning time of PLC will affect the update time of DAP.
9
、
The OS of FB-DAPB(R) shall be new V2.00 above PCB so that multiple sets can be connected. Press
then the OS version is displayed.
10
、
When PROLADDER(or FP07) and DAP are connected to the same set of PLC, to change the program
through PROLADDER is not allowed; if so, the timer information displayed by DAP won’t be correct (In this
Appendix -2
case, the DAP shall be reset).
11
、
Versions after the OS V3.15 (including) of FP-07 can be aimed for DOCs in 16 words of contacts, registers.
1.3
The Main Functions of FB-DAP
The main functions of FB-DAP can be categorized as
:
setter functions of general information, FUN functions of
parameter setting, wireless card reading, and message display function. The details of the functions will be introduced in
the following sections.
1.4
Setter Functions of General Information
FB-DAP can be used as a
〝
TC setter
〞
as well as the access to registers (R
、
D
、
W) and contacts (X
、
Y
、
M
、
S). In the FUN functions in the following sections, it can also be used as write-protect with T
、
C
、
R
、
D
、
X
、
Y
、
M
、
S. There
are two measures to monitor information: ADR (general addresses) and DOC monitoring. The latter shall make DOC
compilation (16 words in English, symbols, numbers) in advance through Proladder or FP07 for T, C, register R/D and
contacts so the DOC can be displayed.
1
、
ADR Monitoring
A. Timer and Counter Monitoring
【
Pressing Keys
】:
or
number
T or C number Cursor position
↓
←
Set value
←
Current value
Status
FB-DAP automatic detecting a decimal point position
B. Registers (R
、
D
、
DR
、
DD
、
WX
、
WY
、
WM
、
WS) and contacts (X
、
Y
、
M
、
S) monitoring
【
Monitored range
】
Type
T
C
D
R
DD
DR
WX
WY
WM
WS
X
Y
M
S
Range
0
|
255
0
|
255
0
|
2943
0
|
8071
0
|
2492
0
|
8070
0
|
240
0
|
240
0
|
1984
0
|
984
0
|
255
0
|
255
0
|
2001
0
|
999
【
Pressing keys
】:
or
+ ( )
or
number
+
+
(
or
or
or
)
(
or
or
or
)
Cursor position
Value
↓
↓
←
Item 1
←
Item 2
↑
Status
Appendix -3
↑
↑
〝
H
〞
indicates hexadecimal
↓
※
WX
、
WY
、
WM
、
WS can display one item only but each
pressing status is available.
Y15
Y0
Note:1、Pressing
can move the cursor up and down or switch between CV or PV.
2、Pressing
or
can decrease or increase the monitored item number.
3、For a monitored item value, input a new value directly and then press
. The status of the
contacts can be changed by pressing
+
.
4、Pressing
+
can change the means to display a value (either with decimal or hexadecimal
system).
2
、
DOC monitoring
←
DOC of T10
←
Current value
↑
Contact status
←
Register DOC
←
Value
Note:1、Pressing
+
can switch the monitoring of ADR and DOC.
2、The display switch between CV (current value) and PV of the timer (counter) can use
.
3、 or
can be moved up or down to next monitored item with DOC.
3
、
Speed monitoring FUN keys(FUN KEY 0
~
9, totaling 10 keys)
【
Pressing keys
】:
+ ( ~ )
B
Direct display of a monitored item set by the client.
Note:1、Items to be monitored can be set from the following “FUN functions”.
2、Items to be monitored can be displayed with general or DOC means.
Appendix -4
↑
↑
1.5
FUN Functions
1.5.1
In and out of FUN functions
■
Enter FUN functions
Press + +
1
、
PASSWORD OPEN
(Password open)
2
、
PASSWORD CLOSE
(Password blocked)
3
、
PASSWORD SET
(Password setting)
4
、
DEFINE FUN KEY
(Self-define speed monitoring function key FUN KEY 0-9)
Press
5
、
DEFINE ALARM
ADDRESS
(Self-define start address of content for display at an alarm)
6
、
DEFINE SOFTKEY
(8-KEY)
(Self-define 8 special keys)
*
7
、
DEFINE SOFTKEY
MODE (8-KEY)
(Enter into the modes of the 8 special keys)
8
、
DEFINE SOFTKEY
(16-KEY)
(Self-define 16 special keys)
*
9
、
ENTER SOFTKEY
MODE(16-KEY)
(Enter into the modes of the 16 special keys)
○
10
、
VOLUME
(Adjust volume)
11
、
SET DAP NO.
(Set DAP number
(
s
)
at multi-link)
○
12
、
MAX. DAP NO.
ON NETWORK(1~16)
(Set the max. DAP numbers on network
(
1-16
)
at multi-link)
○
13
、
WRITE PROTECT
(Data write-in protection)
○
14
、
RF CARD MODE
(RF card mode selection)
○
15
、
RF CARD
START ADDR.
(Start address of a RF card number storage)
*
16
、
ENABLE
KEYS MAPPING
(Corresponding special contacts of ENABLE keys)
*:
Indicates when multiple DAPs are connected, each DAP can be set respectively.
○
:
Indicates when multiple DAPs are connected, the information set by one of them is not available for use until PLC is reset.
■
Exit of FUN functions to general information setter functions. Press
+ + +
Monitored items
Note:1、When several DAPs are connected, information can be stored to PLC (D2944~D3071) if one of the DAP is set in
all the FUN functions (except item 11).
2、After entering FUN 4~15, without password protection, all the FUN functions can be executed by only pressing
. With password protection, it is required to pass it first before executing FUN functions.
3、If it is password-protected, FB-DAP will be set in a password protection status at each beginning of operation.
4、FUN items 1~9 can be entered with numeric keys directly and then go straight to that function.
5、After executing a item of FUN functions, if execution of other items is required, press the three keys
+
again.
Appendix -5
+
Plik z chomika:
artibe22
Inne pliki z tego folderu:
winproladder-tutorial.pdf
(760 KB)
Ch08_Test_Run_Monitoring.pdf
(168 KB)
Ch08_Step_Instruction_Description.pdf
(630 KB)
Ch07_Digital_Outputs.pdf
(290 KB)
Ch07_Advanced_Function_List.pdf
(2187 KB)
Inne foldery tego chomika:
Benedikt
BHP
Dokumenty
Elektronika
Elektryka
Zgłoś jeśli
naruszono regulamin